Tradeco®

Technical data

For 7N and 3.6N - BS EN 459.1 (HL 3.5)

Specifically designed to provide today’s builder with a mortar that does not develop a strength above the one of the masonry units. Elasticity, good water retention, setting time, low capillarity, excellent breathability are the other notable properties of mortars made with Tradeco®. Its low density produces a high yield.

Main Data
Retained at 90µm
< 1%
Retained at 200µm
< 0.5%
Dry density (powder)
< 600 g/l
Whiteness index
Y = 88 (very good reproduction of sand colour)
Tests on mortar prepared according with BS EN459-1 and 459.2 With ISO 679 sand
Compressive strength
7 days 5.5N/mm2 – 28 days 7 N/mm2
Flexural strength
7 days 1.3 N/mm2 – 28 days 2 N/mm2
Test on mortar prepared with 0-3mm common sand at 1:2 binder : sand ratio (1bag+80 litres of sand) 1 : 2.5 1 bag +100 litres sand
Wet density
1600 g/l
1700 g/l
Setting time
2 – 4h 30m
2 – 4h 30m
Water retention
87%
85%
Compressive strength
7 days 3.4 N/mm2– 28 days 4.5N/mm2
2.55 / 3.35
Flexural strength
0.95 N/mm2 – 1.3 N/mm2
0.71 N/mm2 / 0.97 N/mm2
Bonding strength (Tensile)
0.37 N/mm2 – 0.5 N/mm2
0.28 N/mm2 /0.37 N/mm2
Density
7 days 1550 g/l – 28 days 1500 g/l
7 days 1575 g/l – 28 days 1550 g/l
Shrinkage
7 days 0.72 mm.m – 28 days 0.88 mm.m
0.7 – 0.8
Thermal conductivity 28 days
λ 0.49 W/m.K tabulated EN 1745
λ 0.49 W/m.K tabulated EN 1745
Expansion coefficient 28days
>1 mm/m
>1 mm/m
Elasticity Moduli 28 days
5000 MPa
4500 MPa
Capillarity 28 days
0.74 g/dm2 x min1/2
0.8 g/dm2 x min1/2
Vapour Permeability
.8 g.m2/hour.mmHg
0.85g.m2/hour.mmHg
Vapour Resistance
µ 0.115
µ 0.11

Suitable for
Breathable solutions, renders, bedding, pointing, finishing and for saltpeter treatment. Also suitable for hemp plasters, for brick construction and low density masonry. Before starting, always try on a small test area.

Dosages

1) 7 N/mm2 masonry or above
Building mortar: 1 bag + 80 litres of sand
Stipple coats on renders (cast on or sprayed on): 1 bag + 70 litres of well graded sharp sand 0-3mm
Renders/plaster base coat
Manual application: 1 bag + 90 litres of well graded sharp sand
Spray application: 1 bag + 80 litres of well graded sand

2) 3.6N masonry units
Building mortar 1 bag + 100 litres of well graded sand
Water addition: 24 litres per bag of 25 kg binder with dry sand. This can vary depending on moisture of site sands

Mixing
Up to 5 minutes in a conventional drum mixer.

Application
Application by spray gun is possible. Please consult us.

Working temperatures
Not below 8oC or above 30oC. Make sure that high suction materials are thoroughly dampened before application. Avoid rapid drying due to high temperatures or strong winds by curing with a light water mist several times a day if necessary. See Protecting Lime Mortar.

See also Tradeco® Health and Safety Information.